Fixed optics micrometer
Products Measuring ranges Resolution Linearity Measuring rate Miniature laser micrometeroptoCONTROL 1200 2-30 mm 0.5% F.S.O. ± 2% F.S.O. 100 kHz Laser micrometer w. large rangeoptoCONTROL 1202 72-98 mm 0.01% F.S.O. ± 0.2% F.S.O. 400 Hz Online micrometreoptoCONTROL 1220 28 mm 0.01%F.S.O. ± 0.08%F.S.O. 200 Hz Online micrometreoptoCONTROL 2500 34 mm 0.003% F.S.O. ± 0.03% F.S.O. 2.3 kHz Precision micrometreoptoCONTROL 2520 46 mm 0.002% F.S.O. ± 0.03% F.S.O. 2.5 kHz Online micrometreoptoCONTROL 2600 40 mm 0.00025% F.S.O. ± 0.0075% F.S.O. 2.3 kHz Measuring range 2-98 mm Resolution 0.00025-0.5% F.S.O. Linearity 0.00025-0.5% F.S.O. Application Ideal for process control Our micrometers operate based on the ThruBeam principle. A transmitter produces a parallel light curtain that is transmitted via a lens arrangement into the receiving unit. The beam is interrupted if there is an object in the light path. The shadowing generated by this object is recorded by the receiving optical system and output as a geometric value. Several types of ThruBeam technology are used across the four different sensor models in the range so as to cover as wide a field of applications as possible. Optical micrometers can be used for dimensional measurements in production, quality assurance and service tasks. Factors such as the diameter, gap, height, position and also the received amount of light or opacity can be measured. optoCONTROL 1200 is based on the principle of light quantity measurement. The light of a red laser diode is spread out by a lens to a parallel light curtain which is aimed at the receiving unit. In the receiving unit, the light is guided via various filters and lenses through a precision shutter to a light-sensitive detector. The amount of occurring light is provided by analogue electronics and output as an analogue signal. The laser bean for the optoCONTROL 1202 laser micrometers is output from the optical transmitter as a parallel aimed laser beam. The laser line strikes a CCD array in the receiving optical system. The amount of light collected by each of these receiving elements during the integration times is read out separately as analogue voltage and stored as a digital value in a data field after analogue-to-digital conversion. If there is a non-transparent measurement object in the laser line, only the receiving elements of the line outside the shadow zone of the measurement object are illuminated. optoCONTROL 1220 series is specifically designed for measuring edges, diameters and gaps of...